To the Saga synthesis top

About appropriate disposal of polychlorinated biphenyl (PCB) use stabilizers

The last update date:
 

About polychlorinated biphenyl (PCB) use stabilizer

 Stabilizer which PCB is used in is just used, and old stabilizer may just remain in building for business built before March, 1977 in building if we change.

 Use of PCB stabilizer that 40 years or more pass from production deteriorates and explodes, and accident that PCB leaks occurs in the whole country. There is not stabilizer which PCB is used in in the whole country, or Surveys is carried out since PCB special measures law is established in 2001, but accident that PCB leaked from facility where there were PCB not applicable and report in Surveys is reported.

 

 ※About outbreak of explosion accident of PCB-containing fluorescent lamp stabilizer

 

※PCB
Because PCB was generic name of polychlorinated biphenyl compound and was oily material which had "noninflammability" that "it is hard to pyrolyze" property "that the electric insulation characteristics were high" in, it was used as insulating oil such as stabilizers of transformer, condenser and lighting equipment installed in room (kyubikuru) which received high pressure for business use. That carcinogenicity, dermatopathy, the internal organs disorder, hormone are abnormal in PCB; was toxic, and it was for social problem by Kanemi Rice-Oil yusho case that occurred in 1968, and production of PCB was called off in 1972. 
 
 

About disposal of use of PCB stabilizers in time limit

 As for the use of PCB stabilizer, processing is performed under the understanding of location areas middle storage in the PCB processing office of two whole country (Kitakyushu-shi, Fukuoka, Muroran-shi, Hokkaido) of environmental safe business (JESCO). It is prescribed in laws and ordinances that we dispose of use of PCB stabilizer exhausted from Saga in JESCO Kitakyusyu office, and it is until March 31, 2021 during disposal period.

 

 When it is past disposal period, it is decided that disposal facility of JESCO is dismantled and cannot dispose of use of PCB stabilizer. We ask you to confirm person owning building for business before March, 1977 in building whether there is not PCB stabilizer. When use of PCB stabilizer is discovered, we have you push forward Notifecations to the prefecture, disposal procedure in JESCO immediately and would appreciate your doing processing in time limit.

 

 

About distinction method of use of PCB stabilizer

  About fluorescent lamp appliance (office, lesson use) made by from January, 1957 to August, 1972, mercury lamp appliance (for road for high ceiling), low-pressure sodium lamp appliance (for tunnel), use of PCB stabilizer may be used.

PCB is not included in incandescent electric lamp and halogen bulb which are incandescence light emission, LED lamp and EL lamp which are electroluminescence and fluorescent lamp appliance for ordinary household.

 

Distinction flow whether or not PCB is included in stabilizer


When we just use lighting equipment at the time of construction in building for business built before March, 1977, it is necessary to distinguish whether PCB is included in stabilizer of lighting equipment in reference to figure of flow below.PCB stabilizer distinction flow




 

 

Method to distinguish from label (the appearance) of lighting equipment

We may distinguish whether PCB is used from label (the appearance) of lighting equipment.

 

 Fluorescent lamp label

Fluorescent lamp label expansion
(1) The production year
   If it is made after 1973 (Showa 48)
   It is PCB nonuse.
 
(2) Power factor
   Fluorescent lamp appliance of low power factor type is PCB nonuse.
 
(3) Hf lamp
   Fluorescent lamp appliance of use of Hf lamp is PCB nonuse.
 
 

When we distinguish from tablet of stabilizer

Is use of PCB lighting equipment from label (the appearance) of lighting equipment; when cannot distinguish, take off fluorescent tube, light reflector, and it is necessary to distinguish presence of PCB on seeing nameplate put on stabilizer.

Stabilizer which is in fluorescent lamp



 
In the case of magnetism-type stabilizer, PCB may be included in fluorescent lamp appliance. PCB is not included in inverter (electron)-type stabilizer.

In addition, PCB is not used in fluorescent lamp appliance for ordinary household. Please confirm type, power factor than tablet of stabilizer in manufacturer, the production year.

Based on that, you confirm in lighting industry society HP (http://www.jlma.or.jp/kankyo/pcb/index.htm We open with the other window(external link)) in Japan, or please refer to maker window.

 

 

Method to calculate power factor, and to judge

 If tablet of stabilizer can make out, manufacturer of stabilizer disappears and may not distinguish whether it is use of PCB stabilizer. In that case, please calculate power factor by applying values such as the "input voltage" "electric current voltage" "input electric current" "the first electric current" "power consumption" "loss electricity" to reading, the following calculating formula from tablet. As we correspond to high power factor if calculation results are 0.85 (85%) or more, use of PCB stabilizer is possible. PCB is nonuse if less than 0.85 (85%).

 If tablet cannot read, power factor calculation may be possible if it is stabilizer currently using by measuring electric current, the voltage. When you measure, please talk with electrician proprietor.
Power factor calculation example

 

  

※When we cannot read the production year by deterioration of in building for business before March, 1977 and tablet and cannot distinguish by the method mentioned above whether it is use of PCB stabilizer, we consider to be use of PCB stabilizer, and it is necessary to dispose in JESCO Kitakyusyu office.

 

About disposal method of use of PCB stabilizer

When we discover use of PCB stabilizer, it is necessary to dispose in environmental safe business (JESCO) Kitakyusyu office middle storage by the end of March, 2021. At first, you contact sales representative of JESCO Kitakyusyu office, and please push forward procedure for processing. In addition, it is necessary to do Notifecations based on PCB special measures law in Recycling Society Promotion Division of the prefecture.

 

Disposal procedure procedure of use of PCB stabilizer

 Procedure Procedure contents Procedure
 1

 Notifecations (until the every year end of June) based on PCB special measures law

※We submit the style first. In the case of new outbreak, we submit immediately

 Saga
 2 Import load look registration of use of PCB stabilizer JESCO
 3 Small and medium sized enterprise operators reduction system application (only as for the applicable person) JESCO
 4 The disposal consignment contract conclusion of PCB waste JESCO
 5

 The collection of PCB waste transportation consignment contract conclusion

※In special management industrial waste collection transportation work permission suppliers of Saga

 We consign to supplier having guide permit of JESCO Kitakyusyu office

Collection transportation supplier 
 6 We carry out at time when JESCO appoints and handle JESCO
 7

 Notifecations (after consigning disposal such as all PCB waste less than 20 days) based on PCB special measures law

※We submit style No. 4, manifesto A vote

 Saga
 8

 Notifecations (until the next fiscal year end of June of the year when we disposed) based on PCB special measures law

※We submit the style first, manifesto E vote

 Saga

 

Middle storage, environmental safe business (JESCO) Kitakyusyu office We open with the other window(external link) (Phone: 093-522-8588)

It is this about Notifecations based on PCB special measures law
 

 

About supporting systems about Surveys expense of use of PCB stabilizer and disposal

 

Assistance to Surveys expense of use of PCB lighting equipment and expense required for exchange to LED light

There is assistance system of Surveys expense of use of PCB lighting equipment and expense required for exchange to LED light from association of greenhouse gas examination. When there is guidance of offer as open call for participants implementation period is set, we are going to tell even about Saga homepage. For more information about application method, please see homepage of association of greenhouse gas examination.

 

Association of greenhouse gas examination homepage We open with the other window(external link)

 

As for the small and medium sized enterprise operators, it is reduction system

When small and medium sized enterprise operators dispose of PCB waste in JESCO, there is system that 70% of disposal expenses in JESCO are reduced.

(95% are reduced about individual, bankrupt except sole proprietor)

※Expense required for collection transportation is necessary separately.

 

For details, please confirm to the person in charge of JESCO.

 

JESCO homepage (discount for small and medium sized enterprise operators) We open with the other window(external link)

 

Financing facility by Japanese system financing government finance company

PCB waste disposal treatment is targeted for financing of "environment and energy countermeasures fund" (PCB waste disposal connection) in Japanese system financing government finance company. Please refer to the following homepage for the details about financing facility.

 

Homepage We open with the other window(external link) of Japanese system financing government finance company



 

We relate to this page
Inquiry
(ID: 60525)
Saga prefectural government office (corporation number 1000020410004) 〒 840-8570  1-1-59, Jonai, Saga-shi   Tel: 0952-24-2111 (main)     
Copyright© 2016 Saga Prefecture.All Rights Reserved.

Saga prefectural government office (corporation number 1000020410004)

〒840-8570
1-1-59, Jonai, Saga-shi
Tel: 0952-24-2111 (main)
Copyright© 2016 Saga Prefecture.All Rights Reserved.