To the Saga synthesis top

It is ... Freon discharge restraint law ... to all of you handling Freon use apparatus

The last update date:

Let's handle 1 Freon appropriately

 For protection of the ozone layer and prevention of global warming, it is necessary to handle Freon according to each law appropriately.
  •  Air-conditioner of (attention) for business use and frozen refrigeration apparatus → Freon discharge restraint law
  •  Air-conditioner (car air-conditioner) of car → Car Law for the Promotion of Utilization of Recycled Resources
  •  Home air-conditioner and refrigerator-freezer → Home Appliance Recycling Act  

 (attention) Manufacturer says production, apparatus importing for duties use to be for business use.

 

Summary of 2 Freon discharge restraint law

 Freon collection, destruction law was enforced on April 1, 2002, and regulation of the handling of Freon used for air-conditioner for business use and frozen refrigeration apparatus (first-class specific product) as refrigerant began.
 Afterwards, on 1st, the Freon collection, destruction method changed the Freon discharge restraint method and name in April, 2015 so that comprehensive countermeasures for the whole life cycles from production of Freon to the disposal had stolen and was enforced.

 Furthermore, revision for improvement of percentage of debt collection at the time of the disposal is accomplished and will be taken effect on April 1, 2020.                           

 

Freon life cycle

 


 <example of place where first-class specific product is used in>
 (1) Restaurant
  Refrigerator for duties, package air-conditioner, sushi topping case, beer server, ice machine
 (2) Office
  Water fountain, package air-conditioner, turbo refrigerator, chiller (chiringuyunitto), screw refrigerator
 (3) Supermarket
  Refrigeration showcase, frozen showcase, package air-conditioner
 (4) machinaka
  Package air-conditioner, frozen refrigeration unit, vending machine, water fountain for transportation
First-class specific productFirst-class specific product
 
 <main revised contents of the April 1, 2020 enforcement>
 (1) Approach in case of the apparatus disposal
  •  We extend preservation period of blotter of check of apparatus after the delivery completion of Freon for three years
  •  For violation that user does not collect Freon is introduced punishment directly
  •  We oblige to grant of copy of Freon collection finished certificates to waste, recycling supplier
 (2) Approach in case of the apparatus disposal at the time of the building dismantling
  •  We oblige to preservation of confirmation record (prior explanation documents) of having apparatus or not by housebreakers
 (3) Approach when apparatus is taken over
  •  Waste, recycling supplier confirms copying such as Freon collection finished certificates at the time of taking over of apparatus and prohibits taking care of of apparatus which we cannot confirm

Law revision summary

 <reference materials>
 Concrete content (we include revised contents.) of Freon discharge restraint law As for, brochure leaflet, the guide, please see this.
 
 

Duty of manager (user) of 3 first-class specific products

 As a general rule, with manager, we become person (owner) having proprietary rights of the product concerned.

 As for the managers, various approaches are sought.

 

 (1) Compliance rules at the time of use of apparatus

  Oh, setting to place appropriate

  •  You install in appropriate place to prevent the damage of apparatus, and please do environmental maintenance maintenance to set up.

  Check of i apparatus

  •  Please carry out simple check (that is all once in three months) for all first-class specific products.
  •  About constant output or more first-class specific products, please carry out periodic inspection (list shown below) by person having technical knowledge.

(periodic inspection)

Product divisionDivision of the rating output of motor used for compressor or the output of engine driving compressor Frequency of check 
 Refrigeration apparatus and frozen apparatus 7.5kW or more apparatuses More than once a year
 Air-conditioner 50kW or more apparatuses More than once a year
 Air-conditioner Apparatus less than 50kW 7.5kW or more That is all once in three years

 

  Cormorant preventive measure to leak out, principle prohibition of filling not to repair

  •  When refrigerant leak is confirmed, please do check, identification, repair of leak point.
  •  When we confirm leak, trouble, filling of principle Freon is prohibition until we repair.

  Oh, preservation of history checking

  •  You record histories such as check, repair of apparatus, filling, collection of refrigerant to perform appropriate crisis management, and please save. In addition, please store record of check for three years from day when delivery of Freon to discard apparatus was completed.
  •  In the case of apparatus maintenance, please disclose the records such as maintenance suppliers at request concerned.

 (2) Report of Freon calculation leak quantity

  •  When it is carbon dioxide conversion, and quantities of leak at all the proprietor of one year (from April 1 to March 31 of the next year) are 1,000 tons or more, please report to country every year by the last day in degree July.

 (3) Request of filling, collection of Freon

  •  When it is necessary we fill Freon at the time of maintenance of apparatus or to collect, please ask first-class Freon kind filling collection supplier who received registration of the metropolis and districts.
  •  When you are going to do the disposal of apparatus, you deliver Freon to first-class Freon filling collection supplier directly, or you entrust facilities suppliers with delivery of Freon, and please deliver to first-class Freon filling collection supplier.

 (attention) When we discard the apparatus concerned without collecting Freon, it becomes targeted for application of fine 500,000 yen or less immediately. In addition, there are various penal regulations.

 

 (best kind Freon filling collection supplier register in Saga)

  It is register as of March 31, 2020.

 ※ About case that "hikitorishomeisho" (document proving taking care of of Freon) is not issued to by first-class Freon filling collection supplier, report is necessary for prefectural Environment Division.

 ※ It processes first-class specific products dumped illegally and talks with prefectural Environment Division if usual processing based on Freon discharge restraint law is difficult
  Please give me.
 
 <reference materials>
  Concrete content (we include revised contents.) of Freon discharge restraint law As for, brochure leaflet, the guide, please see this.
 

Duty of 4 construction, housebreaker (the specific dismantling construction prime contractor)

  Construction, housebreakers need the following approaches.
 
 (1) When you undertake the dismantling construction of building, you confirm yes or no of first-class specific product beforehand, and you issue document to owner, and please explain the result.
   In addition, please save the document for three years. In addition, it is similar when first-class specific product becomes as a result of confirmation.
 
 (2) When first-class specific product is left for building which undertook the dismantling, have owner collect Freon beforehand, or request from owner
   You receive, and please deliver Freon to first-class Freon filling collection supplier.
 
 (3) You confirm that Freon is collected from first-class specific product, and please deliver apparatus to waste, recycling supplier.
 
 (attention) When we release Freon in the atmosphere, we are targeted for application of imprisonment with work for not more than 1 year or a fine of not more than 500000 yen.
 
 <reference materials>

Duty (after April, 2020) of 5 waste, recycling supplier (enforcers such as first-class specific product taking care of)

  When it is charged or free and leaves user of first-class specific product, please confirm that Freon is collected.

  Specifically, in cases from (1) to (4), taking care of is possible.

 

 (1) When copying of "hikitorishomeisho" of Freon which filling collection supplier issues is attached to apparatus and can confirm that Freon is recovered.

   In this case we save certified copy of "hikitorishomeisho" for three years.

 

 (2) When we register filling collection supplier and receive request of collection of Freon by oneself. "Collection request book" of Freon which user issues then to apparatus

   It is necessary to be attached. In addition, issue the original of "hikitorishomeisho" of Freon after the collection of Freon for user, and of "hikitorishomeisho"

   We save certified copy for three years.

 

 (3) When we are asked delivery to filling collection supplier of Freon by user and receive grant of "trust confirmation." In this case filling that entrusted with collection of Freon

   Receive grant of copying of "hikitorishomeisho" from collection supplier.

 

 (4) Copying of "certificate of acknowledgement" to confirm that Freon which filling collection supplier issues is not filled the apparatus with is attached to apparatus, Freon

   When we can confirm that we are not filled.

 

 (attention 1) When we take over apparatus which cannot confirm that Freon is collected, it becomes targeted for application of fine 500,000 yen or less. In addition, various penal regulations

     There is.

 (attention 2) When correspondence from (1) to (4) is difficult, please talk with Environment Division at the time of the others disaster.

 

 <reference materials>

 

We relate to this page
Inquiry
(ID: 72591)
Saga prefectural government office (corporation number 1000020410004) 〒 840-8570  1-1-59, Jonai, Saga-shi   Tel: 0952-24-2111 (main)     
Copyright© 2016 Saga Prefecture.All Rights Reserved.

Saga prefectural government office (corporation number 1000020410004)

〒840-8570
1-1-59, Jonai, Saga-shi
Tel: 0952-24-2111 (main)
Copyright© 2016 Saga Prefecture.All Rights Reserved.